Introduction:
Water is one of the most important and abundant compounds of
the ecosystem. All living organisms on the earth need water for their survival
and growth. As of now only earth is the planet having about 70 % of water. But
due to increased human population, industrialization, use of fertilizers in the
agriculture and man-made activity it is highly polluted with different harmful
contaminants. Therefore it is necessary that the quality of drinking water
should be checked at regular time interval, because due to use of contaminated
drinking water, human population suffers from varied of water borne diseases. so the study of water parameter is needed for analysis.
The
availability of good quality water is an indispensable feature for preventing
diseases and improving quality of life.
Sample
collection:
We collect sample water in a bottle from mosque side
and fisheries pond in JUST campus.
Physical
characteristics of pond water:
We observe some physical parameters of this sample
water. These are given below-
Color: greenish yellow
Odor: no odor
Turbidity: low turbidity
Temperature: 29.80c
Chemical
characteristics of pond water:
pH:
We measure pH by a pH meter. The pH of the pond water is 7.43
Ammonia:
We measure the amount of ammonia of this pond water
by a portable spectrophotometer. The model of this spectrophotometer is DR 2700™ Portable
Spectrophotometer at Hach USA.
Procedure:
Ø We
measure ammonia by neslar method
Ø Sample
water need to be particle free. We make it particle free by filter paper which
is range from 1 or less micrometer.
Ø Then
we take 25ml DI water and 25ml filter water in a measuring cylinder
Ø We
add 3 drops of mineral stabilizer in
every 25ml because it hinders the formation of color.
Figure: shake/ jar test
Ø Then
shake it
Ø Then we add 3 drops of polyvinyl alcohol
and shake it again
Ø Then
we add 1ml of neslar reagent in every 25ml and shake it
Ø It
shows color change
Ø Then
we take 10ml of DI water in a quartz cell and it place into spectrophotometer,
that shows 0.00 mg/l ,that means there
is no ammonia
Figure: weight machine
Again we take 10ml
sample water into quartz cell and place into spectrophotometer, that shows result 0.61mg/L ammonia
Result and
Discussion:
ü The result gives the device o.61 mg/l
ü Which means the range were maintained
ü NH3-N, N was 380 ness
ü Wavelength eatablish range425 nm.
Figure: result of amonia in the device
precaution:
v Quartz bottle should be use clearly and safe.
water collect
carefully and factor must be maintained